Micro Stage MT 196
| Technical Data MT196 |
|||
| -100-2LM | -200-2LM | ||
| Travel | [mm] | 100 |
200 |
| Accuracy | [µm] | 2 | 2 |
| Repeatability | [counts] | ± 2 |
± 2 |
| Relative deviation from straightness/flatness - over 10 mm - over total length |
[µm] [µm] |
± 0.4 ± 5 |
± 1 ± 10 |
| Max. speed* | [mm/s] | 250 | 250 |
| Max. acceleration* | [m/s2] | 2 | 2 |
| Permissible loads |
Fx [N] Fy [N] Fz [N] |
30 100 200 |
30 100 200 |
| Weight | [kg] | 4.1 | 4.7 |
* depending on load and duty cycle
| Abbreviations | |
| Drive | |
| DC | DC motor |
| SM | stepping motor |
| PM | PiezoLEG |
| LM | piezo linear motor |
| EDLM | synchronous ironless linear motor |
| Measurement system | |
| R | rotary encoder |
| L | incremental linear encoder |
| W | incremental angular encoder |
| Optional accessories | |
| MM | integrated motion controller |
| B | integrated electromagnetic brake |